CIM Information
Prefix:
PLAT
ID:
0480
User Response
1. Reseat rear hdd cage riser n.
2. Remove the following component and identify the problem. a. HDD drive b. HDD cable c.
RAID card d. cage riser n
3. Replace rear hdd cage riser n (n = riser number).
•
80010204-1d09ffff : Numeric sensor [NumericSensorElementName] going low (lower critical) has
asserted. (Fan Riser2A Tach)
This message is for the use case when an implementation has detected a Lower Critical sensor going
low has asserted.
May also be shown as 800102041d09ffff or 0x800102041d09ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Fan Failure
SNMP Trap ID
11
CIM Information
Prefix:
PLAT
ID:
0480
User Response
1. Reseat rear hdd cage riser n.
2. Remove the following component and identify the problem. a. HDD drive b. HDD cable c.
RAID card d. cage riser n
3. Replace rear hdd cage riser n (n = riser number).
•
80010204-1d0affff : Numeric sensor [NumericSensorElementName] going low (lower critical) has
asserted. (Fan Riser2B Tach)
This message is for the use case when an implementation has detected a Lower Critical sensor going
low has asserted.
May also be shown as 800102041d0affff or 0x800102041d0affff
Appendix A. Integrated management module II (IMM2) error messages
449
Summary of Contents for x3650 M5
Page 1: ...Lenovo System x3650 M5 Installation and Service Guide Machine Type 8871 ...
Page 47: ...Figure 35 System board switches jumpers and buttons Chapter 1 The System x3650 M5 server 35 ...
Page 60: ...48 Lenovo System x3650 M5 Installation and Service Guide ...
Page 80: ...68 Lenovo System x3650 M5 Installation and Service Guide ...
Page 124: ...112 Lenovo System x3650 M5 Installation and Service Guide ...
Page 146: ...134 Lenovo System x3650 M5 Installation and Service Guide ...
Page 1322: ...1310 Lenovo System x3650 M5 Installation and Service Guide ...
Page 1330: ...Taiwan BSMI RoHS declaration 1318 Lenovo System x3650 M5 Installation and Service Guide ...
Page 1339: ......
Page 1340: ......