4. Install hard drives or hard drive filler panels, as necessary.
For instructions, see
“Installing a 3.5-inch Hard Drive into the Storage Bay” on
page 46
.
5. Install the I/O Cooling Module. You must ensure that the I/O Cooling Module being
installated is appropriate for the installed HDD Bay Module.
For information about choosing the appropriate cooling module, refer to the Intel
®
Modular Server Spare/Parts List and Configuration Guide
. For instructions on installing
the I/O Cooling module, see
“Installing the I/O Cooling Module” on page 39
.
Replacing the Midplane
Removing the Midplane
To remove the midplane, follow these steps:
1. Review the safety and ESD information at the beginning of this manual and in the
appendices.
2. To avoid data corruption, ensure that drives in the HDD bay module are not online
and actively providing data storage to any of the installed compute modules.
3. Power down all installed compute modules.
4. Power down the Intel
®
Modular Server System MFSYS25/MFSYS35 by unplugging
power cords to all installed power supplies.
5. Remove the Compute Module(s) and/or filler panels.
For instructions, see
“Removing an Intel® Compute Module” on page 53
.
6. Remove the I/O Cooling Module.
For instructions, see
“Removing the I/O Cooling Module” on page 38
.
7. Remove all the installed hard drives and/or hard drive filler panels.
For instructions, see
“Removing the 2.5-inch Hard Disk Drive Bay Module” on
page 54
or
“Removing the 3.5-inch Hard Disk Drive Bay Module” on page 57
.
8. Remove the Hard Disk Drive Bay Module.
For instructions, see
“Removing the 2.5-inch Hard Disk Drive Bay Module” on
page 54
or
“Removing the 3.5-inch Hard Disk Drive Bay Module” on page 57
.
9. Remove the Main Cooling Modules.
For instructions, see
“Removing a Main Cooling Module” on page 36
.
10. Remove the Storage Control Module(s) and/or filler panels.
For instructions, see
“Removing a Storage Control Module” on page 27
.
11. Remove the Ethernet Switch Module(s) and/or filler panels.
For instructions, see
“Removing an Ethernet Switch Module” on page 24
.
12. Remove the Management Module.
Summary of Contents for MFSYS25V2
Page 4: ...iv Intel Modular Server System Service Guide ...
Page 14: ...xiv Intel Modular Server System Service Guide ...
Page 16: ...xvi Intel Modular Server System Service Guide ...
Page 82: ...66 Intel Modular Server System Service Guide ...
Page 137: ...Intel Modular Server System Service Guide 121 Figure 71 Storage Layout Graphical View ...
Page 144: ...128 Intel Modular Server System Service Guide Figure 79 System Information Report ...
Page 172: ...156 Intel Modular Server System Service Guide ...
Page 186: ...170 Intel Modular Server System Service Guide ...
Page 198: ...182 Intel Modular Server System Service Guide ...