4. With a Phillips* screwdriver, remove the four screws securing the hard drive to the
drive carrier (see letter “A” in
Figure 38
). Lift the hard drive from the carrier (see
letter “B” in
Figure 38
) and store the hard drive in an anti-static container or bag.
Figure 38. Removing Hard Drive from a Drive Carrier
5. Install either another hot-swap hard drive or a filler blank in the drive carrier.
6. Install the drive carrier into the empty drive bay module within two minutes; this step
is required to maintain proper airflow throughout the chassis and to ensure proper
system cooling.
AF003171
A
B