Intel
®
Modular Server System Service Guide
57
Removing and Installing the 3.5-inch Hard Disk Drive Bay Module
Removing the 3.5-inch Hard Disk Drive Bay Module
To remove the 3.5-inch hard disk (HDD) drive bay module, follow these steps:
1. Review the safety and ESD information at the beginning of this manual and in the
appendices.
2. To avoid data corruption, ensure that drives in the HDD bay module are not online
and actively providing data storage to any of the installed compute modules.
3. Power down all installed compute modules.
4. Power down the Intel
®
Modular Server System MFSYS25/MFSYS35 by unplugging
power cords to all installed power supplies.
5. Remove the I/O Cooling Module.
For instructions, see
“Removing the I/O Cooling Module” on page 38
.
6. Remove all installed hard drives and hard drive filler panels.
For instructions, see
“Removing a 3.5-inch Hard Drive from the Storage Bay” on
page 49
.
7. Remove the eight screws holding the HDD Bay Module bezel in place (see letter “A”
in
Figure 43
) and remove the bezel (see letter “B” in
Figure 43
).
8. Gently slide the HDD bay module out of the chassis (see letter “C” in
Figure 43
).
There will be some initial resistance as the bay is unseated from the midplane
connectors.
Summary of Contents for MFSYS25V2
Page 4: ...iv Intel Modular Server System Service Guide ...
Page 14: ...xiv Intel Modular Server System Service Guide ...
Page 16: ...xvi Intel Modular Server System Service Guide ...
Page 82: ...66 Intel Modular Server System Service Guide ...
Page 137: ...Intel Modular Server System Service Guide 121 Figure 71 Storage Layout Graphical View ...
Page 144: ...128 Intel Modular Server System Service Guide Figure 79 System Information Report ...
Page 172: ...156 Intel Modular Server System Service Guide ...
Page 186: ...170 Intel Modular Server System Service Guide ...
Page 198: ...182 Intel Modular Server System Service Guide ...