102
Intel
®
Modular Server System Service Guide
Physical Drive Details
The tabs displayed in the system graphic provide detailed information on the selected
physical drive. For a description of these tabs, refer to the following table.
Table 19. Physical Drive Tabs
Physical Drive Help
To quickly access additional help regarding physical drive actions and tabs, click on the
Get Help button in the Shared Drive help box located under the action box.
Clear PFA State
Sets the drive state to OK. The Predictive Failure (PFA) State
indicates that the background PFA scan found bad data blocks or
sectors on the drive.
Clear Stale State
Sets the drive state to OK. Clear Stale State is present if a drive is in
a stale state (the drive has obsolete array information). This can
occur when the drive is taken offline by the user, by physically
removing the drive or by a disk error. When the storage pool is
rebuilt to correct for the missing drive, the drive is marked as ‘stale’.
Start Data Migration
Enables an IT administrator to move data from a defective physical
disk drive to a good physical disk drive.
Table 18. Physical Drive Action Menu
Global Action Menu Item
Description
Create Storage Pool
Designates one or more drives as a storage pool. Global storage
actions are available at all times on the storage screen.
Selected Physical Drive
Action Menu Items
Description
Tab Heading
Description
General
The General tab displays a table with the following information:
•
Current status of the physical drive (i.e., status, health,
operation state)
•
Drive product data (i.e., Drive Number, Manufacturer, Serial
Number, Size, Firmware, Role)
Events
Displays all system events for the selected physical drive.
Storage Pool (displayed if
drive is included in an
existing storage pool)
Displays the Storage Pool property table, which includes information
such as Storage Pool ID, Storage Pool Name, Status, Total Managed
Space, Total Unallocated Space, Number of Physical Drives,
Number of Virtual (Logical) Drives.
Virtual Drives (displayed if
drive is included in a
storage pool with virtual
drives)
Displays the Virtual Drive to Server Mapping table, which includes
virtual drive name, size, RAID level, status, assigned server, and
drive number/position.
Background Tasks
(displayed if drive is
included in a storage pool)
Lists any Active Tasks currently involving the physical drive, such as
creating, expanding, rebuilding, or migrating storage pools or virtual
drives.
Summary of Contents for MFSYS25V2
Page 4: ...iv Intel Modular Server System Service Guide ...
Page 14: ...xiv Intel Modular Server System Service Guide ...
Page 16: ...xvi Intel Modular Server System Service Guide ...
Page 82: ...66 Intel Modular Server System Service Guide ...
Page 137: ...Intel Modular Server System Service Guide 121 Figure 71 Storage Layout Graphical View ...
Page 144: ...128 Intel Modular Server System Service Guide Figure 79 System Information Report ...
Page 172: ...156 Intel Modular Server System Service Guide ...
Page 186: ...170 Intel Modular Server System Service Guide ...
Page 198: ...182 Intel Modular Server System Service Guide ...