Intel
®
Modular Server System Service Guide
29
Installing and Removing the Backup Battery
Installing a Backup Battery
To install a backup battery, follow these steps:
1. Review the safety and ESD information at the beginning of this manual and in the
appendices.
2. Remove the storage control module from the system. For instructions, see
“Removing
a Storage Control Module” on page 27
.
Warning:
You must replace the storage control module with a filler panel or
another storage control module within two minutes.
3. Place the storage control module sideways on a work surface so that its largest surface
area is touching the work surface and the retention lever is on the top.
4. With a Phillips* screwdriver, remove the screw securing the top cover to the storage
control module (see letter “A” in
Figure 16
).
Figure 16. Removing Top Cover from Storage Control Module
5. Slide the cover towards the rear of the storage control module (see letter “B” in
Figure 16
) and lift upward (see letter “C” in
Figure 16
).
A
B
C
AF002563
Summary of Contents for MFSYS25V2
Page 4: ...iv Intel Modular Server System Service Guide ...
Page 14: ...xiv Intel Modular Server System Service Guide ...
Page 16: ...xvi Intel Modular Server System Service Guide ...
Page 82: ...66 Intel Modular Server System Service Guide ...
Page 137: ...Intel Modular Server System Service Guide 121 Figure 71 Storage Layout Graphical View ...
Page 144: ...128 Intel Modular Server System Service Guide Figure 79 System Information Report ...
Page 172: ...156 Intel Modular Server System Service Guide ...
Page 186: ...170 Intel Modular Server System Service Guide ...
Page 198: ...182 Intel Modular Server System Service Guide ...