IDT SMBus Interfaces
PES12T3G2 User Manual
5 - 14
January 28, 2013
Notes
Serial EEPROM Read or Write Operation
Table 5.12 indicates the sequence of data as it is presented on the slave SMBus following the byte
address of the Slave SMBus interface.
Bit
Field
Name
Type
Description
0
BELL
Read/Write
Byte Enable Lower. When set, the byte enable for bits [7:0] of the
data word is enabled.
1
BELM
Read/Write
Byte Enable Lower Middle. When set, the byte enable for bits [15:8]
of the data word is enabled.
2
BEUM
Read/Write
Byte Enable Upper Middle. When set, the byte enable for bits
[23:16] of the data word is enabled.
3
BEUU
Read/Write
Byte Enable Upper. When set, the byte enable for bits [31:24] of the
data word is enabled.
4
OP
Read/Write
CSR Operation. This field encodes the CSR operation to be per-
formed.
0 - CSR write
1 - CSR read
5
0
0
Reserved. Must be zero
6
RERR
Read-Only
and Clear
Read Error. This bit is set if the last CSR read SMBus transaction was
not claimed by a device. Success indicates that the transaction was
claimed and not that the operation completed without error.
7
WERR
Read-Only
and Clear
Write Error. This bit is set if the last CSR write SMBus transaction was
not claimed by a device. Success indicates that the transaction was
claimed and not that the operation completed without error.
Table 5.12 CSR Register Read or Write CMD Field Description
Byte
Position
Field
Name
Description
0
CCODE
Command Code. Slave Command Code field described in Table
5.10.
1
BYTCNT
Byte Count. The byte count field is only transmitted for block type
SMBus transactions. SMBus word and byte accesses to not contain
this field. The byte count field indicates the number of bytes following
the byte count field when performing a write or setting up for a read.
The byte count field is also used when returning data to indicate the
number of following bytes (including status).
2
CMD
Command. This field contains information related to the serial
EEPROM transaction
3
EEADDR
Serial EEPROM Address. This field specifies the address of the
Serial EEPROM on the Master SMBus when the USA bit is set in the
CMD field. Bit zero must be zero and thus the 7-bit address must be
left justified.
Table 5.13 Serial EEPROM Read or Write Operation Byte Sequence
Summary of Contents for 89HPES12T3G2
Page 10: ...IDT Table of Contents PES12T3G2 User Manual iv January 28 2013 Notes...
Page 12: ...IDT List of Tables PES12T3G2 User Manual vi January 28 2013 Notes...
Page 14: ...IDT List of Figures PES12T3G2 User Manual viii January 28 2013 Notes...
Page 18: ...IDT Register List PES12T3G2 User Manual xii January 28 2013 Notes...
Page 46: ...IDT Link Operation PES12T3G2 User Manual 3 10 January 28 2013 Notes...
Page 66: ...IDT SMBus Interfaces PES12T3G2 User Manual 5 18 January 28 2013 Notes...
Page 70: ...IDT Power Management PES12T3G2 User Manual 6 4 January 28 2013 Notes...
Page 138: ...IDT Configuration Registers PES12T3G2 User Manual 8 62 January 28 2013 Notes...