ENGINE (J05E)/TROUBLESHOOTING
2–165
1.
Set the starter key to the "LOCK" position.
2.
Disconnect the intercooler outlet temperature sensor connector.
3.
Use the electrical tester to measure the resistance between the
terminals of the intercooler outlet temperature sensor.
NO
YES
3
Inspect the intercooler outlet temperature sensor unit
THG
E2
SHTS021270300151
Measurement
conditions
Tester
connections
Standard values
Starter key: LOCK
Intercooler outlet
temperature sen-
sor
THG
–
E2
20
C {68
F}:
7.336
–
5.794 k
50
C {122
F}:
2.435
–
1.994 k
Do the measurements meet the standard value?
Go to step 4.
Replace the intercooler outlet temperature
sensor.
Perform "After-inspection work" of INFOR-
MATION section.