81
Program description: base settings - fixed-wing model
phase 3
phase 4
landing
speed
–––
6
receiv out
rx bind
R08
range test
99sec
When you start the range-check, the transmitter’s
output power is significantly reduced, and the blue
LED on the aerial base starts to flash. At the same
time the time display on the transmitter screen starts
counting down, and a double beep sounds every five
seconds.
From five seconds before the end of the range-check
you will hear a triple beep every second. When the
99 seconds of the range-check period have elapsed,
the transmitter switches back to full power, and the
blue LED glows constantly once more.
Within this period walk away from the model, moving
6.
the sticks all the while. If at any point within a distance
of about fifty metres you notice a break in the connec-
tion, attempt to reproduce it.
If the model is fitted with a motor, switch it on in order
7.
to check the system’s interference rejection.
Walk further away from the model until you no longer
8.
have full control over it.
At this point wait until the test period has elapsed, with
9.
the model still switched on and ready for use. When
the range-check period is over, the model should re-
spond again to control commands. It this is not 100%
the case, do not use the system. Contact your nearest
Service Centre of
Graupner
GmbH & Co. KG.
Carry out the range-check before every flight, and
10.
simulate all the servo movements which are likely to
occur in a typical flight. To ensure safe operation of
the model, the range must always be at least fifty me-
tres on the ground.
Caution:
Never initiate a range-check when you are actually
operating a model!
RF transmit
In this menu line you can manually switch the transmit-
ter’s RF transmission on and off again for a specific
model for the current period that the transmitter is
switched on. For example, you might wish to do this to
save power when demonstrating the programming of a
model.
If you switch the transmitter off with the RF
module switched off, next time you switch the trans-
mitter on it will be switched back on again.
Use the arrow buttons
of the left or right-hand
touch-key to move to the “RF module” line, and touch
the central
SET
button of the right-hand touch-key to
activate the value window:
phase 4
landing
6
receiv out
rx bind
R08
range test
99sec
RF transmit
OFF
Now you can use the right-hand arrow buttons to switch
between OFF and ON. Touch the central
SET
button of
the right-hand touch-key again to conclude the input.
Summary of Contents for mx-12 Hott
Page 1: ...Programming Manual 33116 mx 16 HoTT 3 en mx 16...
Page 35: ...35 For your notes...
Page 49: ...49 For your notes...
Page 55: ...55 For your notes...
Page 59: ...59 For your notes...
Page 63: ...63 For your notes...
Page 69: ...69 For your notes...
Page 91: ...91 For your notes...
Page 101: ...101 For your notes...
Page 123: ...123 For your notes...
Page 181: ...181 For your notes...
Page 193: ...193 For your notes...