29
Description of transmitter
transmitter’s screen display should look like this:
1
3
5
7
2
4
6
8
–100%
0%
0%
0%
0%
0%
0%
0%
If this checking procedure shows a result of up to four
times 0% and eight times 100% - depending on the
number of your transmitter’s self-centring stick functions
- then the transmitter’s sticks are perfectly calibrated.
You can conclude the procedure and - if you wish -
erase the model memory you have just created.
If this is not the case, move to the “Stick calibration”
line of the “
HIDDEN MODE
” menu as described at the
start of the preceding double page, and briefly press the
central
SET
button of the right-hand touch-key:
STICK CALIBRATION
0%
With the arrow buttons
of the right-hand touch-key
you can now select in turn the positions of the four stick
planes to be calibrated, for example, those of the left /
right plane of the right-hand stick:
STICK CALIBRATION
0%
Move the “left” flashing arrow marker to the left-hand
end-point using the right-hand stick - again without
exerting pressure …
STICK CALIBRATION
+100%
… and briefly press the central
SET
button of the
right-hand touch-key. In our example this completes the
calibration of the “left-hand” end-point of the right-hand
stick, and the circle in the centre of the stylised stick
plane flashes to confirm this:
STICK CALIBRATION
+100%
Now release the self-centring stick, so that it can take
up its centre position, and again press briefly the central
SET
button to calibrate the centre position. The “right”
triangular marker now starts to flash:
STICK CALIBRATION
0%
Now repeat the calibration procedure for the right-hand
end-point of the right-hand stick. Repeat the procedure
for the other stick planes.
Notes:
If you make a mistake in the calibration process, sim-
•
ply repeat the appropriate step.
Within any one stick plane each of the three calibra-
•
tion positions can be selected directly using the ar-
row buttons
of the left or right-hand touch-key.
Conclude the procedure by briefly pressing the central
ESC
button of the left-hand touch-key, then quit the
“Stick calibration” sub-menu.
Summary of Contents for mx-12 Hott
Page 1: ...Programming Manual 33116 mx 16 HoTT 3 en mx 16...
Page 35: ...35 For your notes...
Page 49: ...49 For your notes...