76
Program description: base settings - fixed-wing model
when the servo position first
falls below
the switching
threshold (max. +150%).
The speed controller or throttle servo remains at
this motor OFF position until you operate the select-
ed switch again, and use the throttle / brake stick to
move the throttle servo or speed controller beyond
the pre-programmed switching threshold.
The default value in the left-hand column for the “motor
OFF” position of the throttle servo is -100%; the default
switching threshold in the centre column is a servo posi-
tion of +150%:
mod name
stick mode
motor at C1
1
idle re.
tail type
normal
GRAUBELE
cut off
–––
+150%
–100%
STO
Programming
This is the procedure for changing the default value for
the “motor OFF” position of the throttle servo: briefly
press the central
SET
button of the right-hand touch-key:
the current setting is now highlighted (dark background).
Now use the arrow buttons of the left or right-hand
touch-key to enter a value at which the motor is reliably
“off”. If you are controlling a throttle servo (carburettor)
it is important to ensure that the throttle servo does not
strike its mechanical end-stop, e.g. -125%:
mod name
stick mode
motor at C1
1
idle re.
tail type
normal
GRAUBELE
cut off
–––
+150%
STO
–125%
The default value in the centre column is deliberately
high, as this enables you to stop the motor over the
maximum possible range of servo travel (or speed con-
troller range) simply by operating the switch; the switch
is assigned in the right-hand column later.
However, if you prefer to set a lower switching threshold,
so that the switch only takes effect when the throttle
servo or speed controller is below a certain point, then
you should reduce the pre-set servo travel from +150%.
This is accomplished by moving the throttle / brake
stick until the throttle servo or speed controller is at the
position you prefer, then briefly pressing the central
SET
button of the right-hand touch-key:
mod name
stick mode
motor at C1
1
idle re.
tail type
normal
GRAUBELE
cut off
–––
+100%
STO
–125%
The final step is to move to the right-hand column
and assign a switch which you would like to use to cut
the motor (in an emergency) or activate the switching
threshold.
mod name
stick mode
motor at C1
1
idle re.
tail type
normal
GRAUBELE
cut off
+100%
STO
–125%
9
Notes:
You must ensure that the throttle servo does not
•
strike its mechanical end-stop when the motor stop
switch is operated.
To set a switching threshold higher than +100%, tem-
•
porarily increase the travel of servo 1 to more than
100% in the “Servo settings” menu, and then restore
the original value once you have stored the switch-
ing threshold.
tail type
mod name
stick mode
motor on C1
1
idle re.
tail type
normal
GRAUBELE
cut off
+100%
–125%
9
When you select “tail type” using the arrow buttons
of the left or right-hand touch-key, you will see
the corresponding input field framed. Touch the central
SET
button of the right-hand touch-key to highlight the
current setting. Now use the arrow buttons of the right-
hand touch-key to select the option which matches your
model:
„normal“:
This setting caters for all models in which
each of the functions elevator and rudder
Summary of Contents for mx-12 Hott
Page 1: ...Programming Manual 33116 mx 16 HoTT 3 en mx 16...
Page 35: ...35 For your notes...
Page 49: ...49 For your notes...
Page 55: ...55 For your notes...
Page 59: ...59 For your notes...
Page 63: ...63 For your notes...
Page 69: ...69 For your notes...
Page 91: ...91 For your notes...
Page 101: ...101 For your notes...
Page 123: ...123 For your notes...
Page 181: ...181 For your notes...
Page 193: ...193 For your notes...