Operating Manual HG G-98830YA | English, Revision 02 | Date: 21.06.2021
82
Chapter 14 – Troubleshooting
Figure 36
Positioning threshold for a normal transponder reading with side lobes
For the complete installation, values must be found that take all transponders into
account.
Figure 37
Test drive over several transponders
Antenna width
Side lobes, before the transponder is
under the antenna
Threshold position detection e.g. 500 units
Uref
Transponder-Code
Recommended threshold, in this
case between 600 and 700 units
Threshold too high, not
every transponder will be detected
Threshold too low, interference
signals are evaluated or no new
transponders are detected,
as the reference voltage does not fall
below the the threshold in some
cases between two transponders