![Gotting HG G-98830 Operating Manual Download Page 39](http://html1.mh-extra.com/html/gotting/hg-g-98830/hg-g-98830_operating-manual_2247547039.webp)
Operating Manual HG G-98830YA | English, Revision 02 | Date: 21.06.2021
39
Interfaces – Chapter 9
6
3964R
HEX
53
16
54
16
30
16
34
16
Set tuning value to 4
ASCII
ST
04
transparent HEX
3D
16
53
16
54
16
30
16
34
16
3E
16
ASCII =
ST
04
>
7
3964R
HEX
53
16
54
16
30
16
35
16
Set tuning value to 5
ASCII
ST
05
transparent HEX
3D
16
53
16
54
16
30
16
35
16
3F
16
ASCII =
ST
05
?
8
3964R
HEX
53
16
54
16
30
16
36
16
Set tuning value to 6
ASCII
ST
06
transparent HEX
3D
16
53
16
54
16
30
16
36
16
3C
16
ASCII =
ST
06
<
9
3964R
HEX
53
16
54
16
30
16
37
16
Set tuning value to 7
ASCII
ST
07
transparent HEX
3D
16
53
16
54
16
30
16
37
16
3D
16
ASCII =
ST
07
=
10
3964R
HEX
53
16
54
16
30
16
38
16
Set tuning value to 8
ASCII
ST
08
transparent HEX
3D
16
53
16
54
16
30
16
38
16
32
16
ASCII =
ST
08
2
11
3964R
HEX
53
16
54
16
30
16
39
16
Set tuning value to 9
ASCII
ST
09
transparent HEX
3D
16
53
16
54
16
30
16
39
16
33
16
ASCII =
ST
09
3
12
3964R
HEX
53
16
54
16
31
16
30
16
Set tuning value to 10
ASCII
ST
10
transparent HEX
3D
16
53
16
54
16
31
16
30
16
3B
16
ASCII =
ST
10
;
13
3964R
HEX
53
16
54
16
31
16
31
16
Set tuning value to 11
ASCII
ST
11
transparent HEX
3D
16
53
16
54
16
31
16
31
16
3A
16
ASCII =
ST
11
:
14
3964R
HEX
53
16
54
16
31
16
32
16
Set tuning value to 12
ASCII
ST
12
transparent HEX
3D
16
53
16
54
16
31
16
32
16
39
16
ASCII =
ST
12
9
Table 10
List of system commands (part 2 of 4)
No. Procedure
Start Command
Bytes
Parameter
Bytes
Check-
sum *) Description