Chapter 10 – Configuration of the System via the Service Interface
To adjust the output type:
Press the key
and enter the desired value.
Setting the interval of data transmission
If you have selected the output type
permanent (1)
you have to define the intervals
of data transmission with the parameter
(S)erial Data Period
.
Value range:
4 … 500 ms
To set the interval of data transmission:
Make sure that the configured telegram can be transmitted at the selected
baud rate in the set time (see Figure 21 on page 36).
Press the key
and enter the desired value.
Freezing the telegram output
With the parameter
(F)reeze Values for n Telegrams
you can "freeze" the output of
the Y-deviation for 0 to 10 telegrams, i.e. the values are retained at the time of the
positioning pulse output.
Value range:
0 … 10
In order to freeze the telegram output:
Press the key
and enter the number of telegrams.
10.2.6 (T)ime & Code
In the
(T)ime & Code
menu, you set the values for the transponder decoding, the po
-
sition calculation and the positioning pulse.
To switch from the main menu to the menu
(T)ime & Code
:
Press the key
.