Operating Manual HG G-98830YA | English, Revision 02 | Date: 21.06.2021
68
Chapter 10 – Configuration of the System via the Service Interface
Sending a control message (heartbeat)
With the parameter
(H)eartbeat time
you can change the so-called heartbeat time.
A control message is then sent cyclically.
If you set the time to 0, no message will be transmitted and Node Guarding will be
activated (see 9.5.3 „Node-Guarding“ on page 46).
Value range
0
10 … 32000 ms
To send a control message:
Press the key
and enter the desired value.
(D)eactivate Autostart
With the parameter
(A)utostart
you can (de)activate the autostart.
Selection:
0 = Autostart is deactivated. After power-on only the heartbeat message will be
transmitted (if it is activated). The antenna changes to mode
preoperational
.
1 = Autostart is activated. After power-on the heartbeat-message (if it is acti
-
vated) and the PDOs will be transmitted. The antenna changes to mode
opera
-
tional
.
To (de)activate Autostart:
Press the key
and enter the desired value.
Freeze telegram output
With the parameter
(F)reeze Values for n Telegrams
you can "freeze" the output of
the Y-deviation for 0 to 20 telegrams, i.e. the values are retained at the time of the
positioning pulse output.
Value range:
0 … 20
To freeze the telegram output:
Press the button
and enter the number of telegrams.
Set byte order
With the parameter
(O)rder of Data Transfer
you select whether the highest byte is
to be output first or last.
0 = HiByte first
1 = LowByte first
To set the byte order:
Press the key
and enter the desired value.