Operating Manual HG G-98830YA | English, Revision 02 | Date: 21.06.2021
59
Configuration of the System via the Service Interface – Chapter 10
To activate the output of a positioning pulse after decoding:
Press the key
and enter the desired value.
Setting the voltage for the positioning pulse output
The
(L)evel for Positioning/Calculation
parameter determines the voltage S at which
the positioning pulse output is activated to suppress false outputs caused by anten
-
na side lobes (see Figure 36 on page 83).
With the parameter
(L)evel for Positioning/Calculation
you determine from which
voltage S the positioning pulse output is enabled to suppress false outputs due to
antenna side lobes (see Figure 36 on page 82).
Value range:
20 … 1023
To set the voltage for the positioning pulse output:
Press the key
and enter the desired value.
Setting the duration of the positioning pulse
With the parameter
(P)osi-Pulse Time
you determine the duration of the positioning
pulse in 1 ms intervals.
Value range
n * 1 ms
To determine the duration of the positioning pulse:
Press the key
and enter the desired value.
Setting the number of positioning pulses
With the parameter
(O)ne Positioning Pulse per Crossing
you define whether each
crossing of the antenna center axis generates a positioning pulse (e.g. when moving
back and forth directly over a transponder), or whether only one pulse is output per
crossing of a transponder.
To release the positioning pulse again, the voltage S must then fall below the
Thresh
-
old for Calculation-Positioning
(see 10.2.5 „(S)erial Output“ on page 52).
Selection:
0 = Several positioning pulses are output when the same transponder is passed
over several times.
1 = Only one positioning pulse is output when the same transponder is passed
over several times.
To select this function:
Press the key
.
To deactivate this function again:
Press the key
one more time.
Setting the switch-off behavior of the positioning pulse
With the parameter
(X) Timed Positioning Pulse
you can choose whether the corre
-
sponding bit of the positioning pulse in the system status is switched off after the
time set with
or after the voltage S drops below the threshold set with
.