![Geehy SEMICONDUCTOR APM32F405 Series User Manual Download Page 633](http://html1.mh-extra.com/html/geehy-semiconductor/apm32f405-series/apm32f405-series_user-manual_573630633.webp)
www.geehy.com Page 632
Reset value: 0x0000 0000
Field
Name
R/W
Description
0
AWDFLG1
R
Analog Watchdog Flag of ADC1
1
EOCFLG1
R
End of Conversion Flag of ADC1
2
INJEOCFLG1
R
Injected Channel End Of Conversion Flag of ADC1
3
INJCSFLG1
R
Injected Channel Start Flag of ADC1
4
REGCSFLG1
R
Regular Channel Start Flag of ADC1
5
OVRFLG1
R
Overrun Flag of ADC1
7:6
Reserved
8
AWDFLG2
R
Analog Watchdog Flag of ADC2
9
EOCFLG2
R
End of Conversion Flag of ADC2
10
INJEOCFLG2
R
Injected Channel End Of Conversion Flag of ADC2
11
INJCSFLG2
R
Injected Channel Start Flag of ADC2
12
REGCSFLG2
R
Regular Channel Start Flag of ADC2
13
OVRFLG2
R
Overrun Flag of ADC2
15:14
Reserved
16
AWDFLG3
R
Analog Watchdog Flag of ADC3
17
EOCFLG3
R
End of Conversion Flag of ADC3
18
INJEOCFLG3
R
Injected Channel End Of Conversion Flag of ADC3
19
INJCSFLG3
R
Injected Channel Start Flag of ADC3
20
REGCSFLG3
R
Regular Channel Start Flag of ADC3
21
OVRFLG3
R
Overrun Flag of ADC3
31:22
Reserved
ADC general-purpose control register (ADC_CCTRL)
Offset address: 0x04 (this offset address is only related to ADC1 base
0x300)
Reset value: 0x0000 0000
Field
Name
R/W
Description
4:0
ADCMSEL
R/W
ADC mode selection
All ADC are independent
00000: Independent mode
Dual mode: ADC1 and ADC2 work together, while ADC3 is independent
0001: Regular simul injected simultaneous combined
mode
00010: Regular simul alternate trigger combined mode
00011: Reserved
00101: Only injected simultaneous mode
00110: Only regular simultaneous mode