![Geehy SEMICONDUCTOR APM32F405 Series User Manual Download Page 628](http://html1.mh-extra.com/html/geehy-semiconductor/apm32f405-series/apm32f405-series_user-manual_573630628.webp)
www.geehy.com Page 627
Field
Name
R/W
Description
1: EOCFLG bit will be set to 1 at the end of each regular
conversion
11
DALIGNCFG
R/W
Data Alignment Mode Configure
0: Right alignment
1: Left alignment
15:12
Reserved
19:16 INJGEXTTRGSEL R/W
Select the External Trigger Event to Start the Injected Group
Conversion
0000: CC4 event of timer 1
0001: TRGO event of timer 1
0010: CC1 event of timer 2
0011: TRGO event of timer 2
0100: CC2 event of timer 3
0101: CC4 event of timer 3
0110: CC1 event of timer 4
0111: CC2 event of timer 4
1000: CC3 event of timer 4
1001: TRGO event of timer 4
1010: CC4 event of timer 5
1011: TRGO event of timer 5
1100: CC2 event of timer 8
1101: CC3 event of timer 8
1110: CC4 event of timer 8
1111: EINT Line 15
21:20
INJEXTTRGEN
R/W
Enable the External Trigger for Injected Channels
00: Trigger detection is disabled
01: Trigger detection on rising edge
10: Trigger detection on falling edge
11: Trigger detection on rising edge and falling edge
22
INJSWSC
R/W
Start Conversion of Injected Channels
0: Reset state
1: Start conversion of injected channels
23
Reserved
27:24 REGEXTTRGSEL R/W
Select the External Trigger Event to Start the Regular Group
Conversion
0000: CC1 event of timer 1
0001: CC2 event of timer 1
0010: CC3 event of timer 1
0011: CC2 event of timer 2
0100: CC3 event of timer 2
0101: CC4 event of timer 2
0110: TRGO event of timer 2
0111: CC1 event of timer 3
1000: TRGO event of timer 3
1001: CC4 event of timer 4
1010: CC1 event of timer 5
1011: CC2 event of timer 5
1100: CC3 event of timer 5
1101: CC1 event of timer 8
1110: TRGO event of timer 8
1111: EINT Line 11