FR200 Series Vector control inverter
- 56 -
5.1 Standard Function Parameters
Table 5-1
Standard Function Parameters
Param.
Parameter Name
Setting Range
Default
Attr
Group F00: System Parameters
F00.00
Setting of User
Password
0
~
65535
0
×
F00.01
Display of Parameters
0: Display all parameters
1
×
1: Only display F00.00, F00.01 and
user-defined parameters
F17.00
~
F17.29
2: Only display A0-00, A0-01, and
the parameters different with
factory default
F00.02
Parameter Protection
0: All parameter programmable
0
×
1: Only F00.02 and this parameter
programmable
F00.03
G/P type display
0: G type (constant torque load)
0
×
1: P type (variable torque load
e.g. fan and pump)
F00.04
Parameter Initialization
0: No operation
0
×
1: Restore all parameters to factory
default (excluding motor
parameters)
2: Clear fault record
3: Restore user backup
parameters
4: Back up currentuser parameters
F00.05
Copy of Parameters
0: No operation
0
×
1: Upload parameter
2: Download parameter (excluding
motor parameters)
3: Download parameter (including
motor parameters)
F00.06
Parameter
editing mode
0:Editable via keypad and
RS485
0
×
1:Editable via keypad
2:Editable via RS485
F00.08
Motor 1 control mode
0: Voltage/Frequency (V/F)
control
1
×
1:Sensor-less vector control 1
2: Sensor-less vector control 2
F00.09
DI7/HI input mode
0:Digital input terminal 7
0
×
1: Pulse input
F00.10
AI1\AI2\AI3 input mode
Unit's place: AI1
000
×
0:
Analog input
1: Digital input
Decade: AI2 (same as AI1)
Hundreds place: AI3 (same as AI1)
F00.11
Y2/HO input mode
0: Digital 0utput terminal 2
0
×
1: Pulse output
F00.12
PWM optimization
Unit's place:
PWM modulation
mode
000
×
0: Fixed carrier
1: Random carrier
2: Derating of fixed carrier
3: Derating of random carrier