FR200 Series Vector control inverter
- 19 -
-type
、
1.8 Th -type
、
2 Th -type
)
Acceleration
and
deceleration
Curve
Line or curve acceleration and deceleration mode.
Four kinds of acceleration and deceleration time
,
Ramp
Time Range :0.0
~
6000.0s
DC brake
DC brake start frequency: 0.00
~
600.00Hz
DC brake time:0.0s
~
10.0s
DC brake current
:
0.0%
~
150.0%
Basic functions
Jog brake
Jog frequency range
:
0.00Hz
~
50.00Hz.
Jog deceleration time: 0.0s
~
6000.0s.
Simple PLC
、
Multi-speed
Through the built-in PLC or control terminal to achieve
up to 16 speed running
Built-in PID
Facilitate the realization of process control loop control
system
Automatic
voltage
adjustment
(
AVR
)
When the grid voltage changes, can automatically
maintain a constant output voltage
Fast current
limit function
Minimize over current fault protection inverter running
Over voltage
Over current
System automatically limits of current and voltage during
operation to prevent frequent
Run
Command
source
Given the control panel, control terminal, serial
communication port given.
Frequency
given
Sevkeinradlswoafysfrtoeqsuweintcchy sources: digital
setting, keyboard potentiometer setting, analog
Voltage, given analog current reference pulse is given,
the serial port is given, multi-speed given, PLC is given,
the process PI D reference. There are several ways to
switch
Input terminal
7 Switch input terminals, one way to make high-speed
pulse input.
3-channel analog inputs, including 2-way 0
~
10V / 0
~
20mA voltage and current options,
a way to support -10
~
+10 V input
output
terminal
2-way switch output terminal, which supports a
maximum road speed 100kHz pulse output.
2 relay output terminals.
2 analog output terminal, and optional voltage and
current.
Featured
functions
Parameter copy
、
parameter backup
、
flexible parameter displayed &
hidden. Common DC bus
(
Contains below 30 KW
)
.
Various master & auxiliary command and switchover.
Reliable speed search started.
A variety of Accel / Decel curves programmable.
Timing control
、
fixed length control
、
count function.
Three faults recorded.
Over excitation brake
、
overvoltage stall protection programmable
、
under
voltage stall protection programmable
、
restart upon power loss.
Four kinds of Accel/Decel time.
Motor thermal protection.
Flexible fan control.
Process PID control
、
simple PLC
、
16-step speed control programmable.
Wobble frequency control.
Multi-functional key programmable
、
field-weakening control.
High-precision torque control
、
V/f separated control
、
torque control at