FR200 Series Vector control inverter
- 65 -
2: 1.2nd power V/F
3: 1.4th power V/F
4: 1.6th power V/F
5: 1.8th power V/F
6: 2.0nd power V/F
7: V/F complete separation
8: V/F half separation
9: 1.2 power inverse curve V/F
10
:
1.4 power inverse curve V/F
11
:
1.6 power inverse curve V/F
12
:
1.8 power inverse curve V/F
13
:
2.0 power inverse curve V/F
F09.01
Torque boost
0.1%
–30.0% 0.0% (fixed torque
boost)
0.0%
△
F09.02
Cut-off frequency of torque
boost
0.00
~
Fmax
50.00Hz
△
F09.03
Multi-point V/F frequency
1(F1)
0.00
~
F09.05
0.00Hz
△
F09.04
Multi-point V/F voltage 1
(V1)
0.0
~
100.0
0.0%
△
F09.05
Multi-point V/F frequency
2(F2)
F09.03
~
F09.05
0.00Hz
△
F09.06
Multi-point V/F voltage 2
(V2)
0.0
~
100.0
0.0%
△
F09.07
Multi-point V/F frequency
3(F3)
F09.05
~
F09.09
0.00Hz
△
F09.08
Multi-point V/F voltage 3
(V3)
0.0
~
100.0
0.0%
△
F09.09
Multi-point V/F frequency
4(F4)
F09.07
~
rated motor frequency
50.00Hz
△
F09.10
Multi-point V/F voltage 4
(V4)
0.0
~
100.0 Ue=100.0%
100.0%
△
F09.11
V/F slip compensation
gain
0.0
~
300.0%
0.0%
△
F09.12
Stator voltagedrop
compensation gain
0.0
~
200.0%
100.0%
△
F09.13
Excitation boost gain
0.0
~
200.0%
100.0%
△
F09.14
Oscillation Suppression
0.0
~
300.0%
Model
defined
△
F09.15
Voltage source for V/F
separation
0: Digital setting (F09.16)
0
×
1:keypad potentiometer
2
:
AI1
3: Multi-reference
4: Pulse setting ( DI7/HI )
5: PID
6
:
AI2
7
:
AI3
F09.16
Voltage digital setting for
V/F separation
0 V to rated motor voltage
0.0%
△
F09.17
Voltage rise time of V/F
separation
0.0
~
6000.0s
It indicates the time for the
voltage rising from 0 V to rated
Motor voltage.
0.1s
△
Group F10 Vector Control Parameters of Motor 1
F10.00
Speed/torque control
0: speed control
0
×