- 57 -
Decade: PWM modulation mode
0: Seven-segment mode
1: Five-segment mode
2: Five-segment and
seven-segment automatic
switchover
Hundreds place: over-modulation
adjustment
0: Disabled
1: Enabled
F00.13
Carrier frequency
0.700
~
16.000kHz
Model
defined
△
F00.14
Upper carrier
frequency
0.700
~
16.000kHz
8.000kHz
×
F00.15
Lower carrier
frequency
0.700
~
16.000kHz
2.000kHz
×
F00.16
Output voltage
5.0
~
100.0%
100.0%
×
F00.17
AVR
0: Disabled
0
×
1: Enabled
2: AVR is disabled if the DC
bus voltage > the rated
voltage of DC bus, and it will be
enabled if the DC bus voltage≤the
rated voltage of DC bus.
F00.18
Fan control
0: Run at power-on
1
×
1: Fan working during running
F00.19
Factory password
0
~
65535
0
×
F00.20
Inverter rated power
0.2
~
710.0kW
Model
defined
⊙
F00.21
Inverter rated voltage
60
~
660V
Model
defined
⊙
F00.22
Inverter rated current
0.1
~
1500.0A
Model
defined
⊙
F00.23
Software version
0.00
~
655.35
Model
defined
⊙
F00.24
Dealer password
0
~
65535
0
×
F00.25
Setting operation time
0
~
65535h(0: Invaild)
0h
×
F00.26
Inverter application
0: General purpose application
1: Fireworks machine
0
×
Group F00: Frequency Command
F01.00
Frequency source
selection
0: Master frequency source
0
×
1:
Auxiliary frequency source
2: Auxiliary
3: Master - Auxiliary
4: MAX{Master, Auxiliary }
5: MIN {Master, Auxiliary }
F01.01
Master Frequency
Command Source
0:Master digital setting (F01.02)
1
×
1: keypad potentiometer
2: Analog input AI1
3: Communication
4: Multi-reference
5: PLC
6: Process PID output
7: X7/HI pulse input