FR200 Series Vector control inverter
- 126 -
F17.26
User-defined Display
Parameter 26
Range:00.00
~
49.99
Default:13.09
F17.27
User-defined Display
Parameter 27
Range:00.00
~
49.99
Default:00.00
F17.28
User-defined Display
Parameter 28
Range:00.00
~
49.99
Default:00.00
F17.29
User-defined Display
Parameter 29
Range:00.00
~
49.99
Default:00.00
F17 is user-defined parameter group. You can select the required parameters from all FR200
functions codes and add them into this group, convenient for view and modification.Description of
Function Codes FR200 User Manual Group F17 provides a maximum of 30 user-defined parameters.
If "00.00" is displayed, it indicates that group F17 is null. After you enter user-defined function code
mode, the displayed parameters are defined by F17.00 to F17.29 and the sequence is consistent with
that in group F17.
Group U00 Status Monitoring
Group U00 is used to monitor the AC drive's running state. You can view the parameter values by
using keypad, convenient for on-site commissioning, or from the host computer by means of
communication (address: 0x3000
~
0x3020). Status monitoring parameters in the running and stop
state are defined by F16.03 and F16.103.
U00.00
Running frequency
Range:0.00
~
Fup
Default:0.00Hz
U00.01
Set frequency
Range:0.00
~
Fmax
Default:0.00Hz
U00.02
Output voltage
Range:0
~
660V
Default:0V
U00.03
Output current
Range:0.0
~
3000.0A
Default:0.0A
U00.04
Output power
Range:-3000.0
~
3000.0kW
Default:0.0kW
U00.05
Estimated Motor Speed
Range:0
~
60000rpm
Default:0rpm
U00.06
Bus voltage
Range:0
~
1200V
Default:0V
U00.07
Synchronous
Frequency
Range:0.00
~
Fup
Default:0.00Hz
U00.08
PLC step
Range:1
~
15
Default:1
U00.09
Program Operation
Time
Range:0.0
~
6000.0s(h)
Default:0.0s(h)
U00.10
PID set
Range:0
~
60000
Default:0
U00.11
PID feedback
Range:0
~
60000
Default:0
They display the PID setting value and PID feedback value.
PID fe
U00.12
Status of DI1
~
DI5
digital input terminal
Range:00000
~
11111
Default:00000
0 means terminal input status is OFF, while 1 means terminal input status is ON.
Unit's place
:
DI1
Decade
:
DI2
Hundreds place
:
DI3
Thousands place
:
DI4
U00.13
Status of DI6
~
DI7
digital input terminal
Range: 00
~
11
Default: 00
Ten thousands place
:
DI5
0 means terminal input status is OFF, while 1 means terminal input status is ON.
Unit's place
:
DI6
Decade
:
DI7
U00.14
Status of digital output
terminal
Range: 0000
~
1111
Default: 0000
0 means terminal input status is OFF, while 1 means terminal input status is ON.