FR200 Series Vector control inverter
- 81 -
F00.26
Inverter application
Range
:
0
~
1
Default
:
0
Inverter application
0
:
General purpose application
1
:
Fireworks machine
Group F00 Frequency command
Master frequency
source
Auxiliary
frequency source
Terminal UP
/DOWN
+
+
-
Max
Min
+
x
+
AI1
x
AI2
0
1
2
3
4
5
6
7
Switched by
terminal
Switched by
terminal
Jog
frequency
Command frequency
Fig. 6-1
F01.00
Frequency source
selection
Range:0
~
7
Default: 0
0: Master frequency source
The frequency source is determined by master frequency source F01.01.
1: Auxiliary frequency source
The frequency source is determined by auxiliary frequency source F01.03.
2: Auxiliary
The frequency source is determined by Auxiliary.
3: Master - Auxiliary
The frequency source is determined by Master - Auxiliary.
4: MAX {Master, Auxiliary}
The frequency source is determined by MAX {Master, Auxiliary}.
5: MIN {Master, Auxiliary}
The frequency source is determined by MIN {Master, Auxiliary}.
6: AI1 Auxiliary)
The frequency source is determined by AI1*( Auxiliary).
7:
Auxiliary)
The frequency source is determined by AI2*( Auxiliary).
F01.01
Master frequency source selection
Range:0
~
9
Default:1
0: Digital setting (F01.02)
When the inverter is powered on, the value of F01.02 is taken as the master frequency source.
1: Keypad potentiometer
2: Analog input AI1
AI1 and AI2 are (0
~
10V) voltage input and (0
~
20mA) current input programmable. Voltage or
current input can be selected through toggle switches AI1 and AI2 on control board.
When using external voltage/current analog input to the drive, the connection diagram is shown
as Fig. 6-2: