FR200 Series Vector control inverter
- 62 -
F05.09
Detection width of
frequency attained
0.00
~
20.00Hz
5.00Hz
×
F05.10
FDT1 upper bound
0.00
~
Fmax
30.00Hz
×
F05.11
FDT1 lower bound
0.00
~
Fmax
30.00Hz
×
F05.12
FDT2 upper bound
0.00
~
Fmax
30.00Hz
×
F05.13
FDT2 lower bound
0.00
~
Fmax
30.00Hz
×
F05.14
Consecutive running
time
0.0
~
6000.0Min 0.0:Disabled
0.0Min
×
F05.15
Accumulative power-on
time setting
0
~
65535h 0:Disabled
0h
×
F05.16
Accumulative running
time setting
0
~
65535h 0:Disabled
0h
×
F05.17
Brake control selection
0: Disabled
0
×
1: Enabled
F05.18
Brake opened frequency
Closed frequency ~30.00Hz
2.50Hz
×
F05.19
Brake opened current
0.0~200.0%
0.0%
△
F05.20
Brake open waiting time
0.00~10.00s
0.00s
×
F05.21
Brake open operating time
0.00~10.00s
0.50s
×
F05.22
Brake closed frequency
0.00Hz~opened frequency
2.00Hz
×
F05.23
Brake close waiting time
0.00~10.00s
0.00s
×
F05.24
Brake close operating time
0.00~10.00s
0.00s
×
Group F06 Analog and Pulse Input
F06.00
Minimum input of curve
AI1
0.0%
~
input of inflection point1
of curve AI1
0.0%
△
F06.01
Set value corresponding
to minimum input of
curve AI1
-100.0
~
100.0%
0.0%
△
F06.02
Input of inflection point
1 of curve AI1
Minimum input of curve AI1
~
Input
of inflection point 2 of curve AI1
25.0%
△
F06.03
Set value corresponding
to input of inflection
point 1 of curve AI1
-100.0
~
100.0%
25.0%
△
F06.04
Input of inflection point
2 of curve AI1
Input of inflection point 1 of curve
AI1
~
Maximum input of curve AI1
75.0%
△
F06.05
Set value corresponding
to input of inflection
point 2 of curve AI1
-100.0
~
100.0%
75.0%
△
F06.06
Maximum input of curve
AI1
Input of inflection point 2 of curve
AI1
~
100.0%
100.0%
△
F06.07
Set value corresponding
to maximum input of
curve AI1
-100.0
~
100.0%
100.0%
△
F06.08
Minimum input of curve
AI2
0.0%
~
input of inflection point1 of
curve AI2
0.0%
△
F06.09
Set value corresponding
to minimum input of
curve AI2
-100.0
~
100.0%
0.0%
△
F06.10
Input of inflection point
1 of curve AI2
Minimum input of curve AI1
~
Input
of inflection point 2 of curve AI2
25.0%
△
F06.11
Set value corresponding
to input of inflection
point 1 of curve AI2
-100.0
~
100.0%
25.0%
△
F06.12
Input of inflection point
2 of curve AI2
Input of inflection point 1 of curve
AI2
~
Maximum input of curve AI2
75.0%
△
F06.13
Set value corresponding
-100.0
~
100.0%
75.0%
△