FR200 Series Vector control inverter
- 69 -
F11.35
Motor temperature sensor
type
0: Disabled
0
×
1: PT100
2: PT1000
F11.36
Motor temperature sensor
current source port
0: Disabled
0
×
1: AO1
2: AO2
F11.37
Motor temperature sensor
input channels
0: Disabled
0
×
1: AI1
2: AI2
3: AI3
F11.38
Motor temperature
warning action threshold
0
~
200
℃
90
℃
△
F11.39
Motor temperature
protection action threshold
0
~
200
℃
110
℃
△
Group F12: Multi-Reference and Simple PLC Function
F12.00
Reference 0
-100.0
~
100.0%
0.0%
△
F12.01
Reference 1
-100.0
~
100.0%
0.0%
△
F12.02
Reference 2
-100.0
~
100.0%
0.0%
△
F12.03
Reference 3
-100.0
~
100.0%
0.0%
△
F12.04
Reference 4
-100.0
~
100.0%
0.0%
△
F12.05
Reference 5
-100.0
~
100.0%
0.0%
△
F12.06
Reference 6
-100.0
~
100.0%
0.0%
△
F12.07
Reference 7
-100.0
~
100.0%
0.0%
△
F12.08
Reference 8
-100.0
~
100.0%
0.0%
△
F12.09
Reference 9
-100.0
~
100.0%
0.0%
△
F12.10
Reference 10
-100.0
~
100.0%
0.0%
△
F12.11
Reference 11
-100.0
~
100.0%
0.0%
△
F12.12
Reference 12
-100.0
~
100.0%
0.0%
△
F12.13
Reference 13
-100.0
~
100.0%
0.0%
△
F12.14
Reference 14
-100.0
~
100.0%
0.0%
△
F12.15
Reference 15
-100.0
~
100.0%
0.0%
△
F12.16
Reference 0 source
0: Digital setting
(
F12.00)
0
×
1:keypad potentiometer
2
:
AI1
3: Process PID output
4: X7/HI pulse input
5
:
AI2
6
:
AI3
F12.17
Running mode of simple
PLC
Unit's place: PLC running mode
0000
×
0: Stop after a single cycle
1: Continue to run with the last
frequency after a single cycle
2: Repeat cycles
Decade: started mode
0: Continue to run from the step of
stop (or fault)
1: Run from the first step
“multi-step frequency 0”
2: Run from the eighth step
“multi-step frequency 8”