FR200 Series Vector control inverter
- 67 -
5: Pulse setting ( DI7/HI )
Group F11 Protection Parameters
F11.00
Current limit control
0: Current limit disabled
2
×
1: Current limit mode 1
2: Current limit mode 2
F11.01
Current limit
100.0
~
200.0%
150.0%
×
F11.02
Frequency decreasing
time(limit current in
constant speed operation)
0.0
~
6000.0s
5.0s
△
F11.03
Current limit mode 2
proportion gain
0.1
~
100.0%
3.0%
△
F11.04
Current limit mode 2
integral time
0.000
~
1.000s
0.010s
△
F11.05
Overvoltage Stall Control
0: Overvoltage stall disabled
1
×
1: Overvoltage stall mode 1
2: Overvoltage stall mode 2
F11.06
Overvoltage Stall
Voltage
120.0
~
150.0%
130.0%
×
F11.07
Overvoltage Stall
Mode 2 Proportion Gain
0.1
~
100.0%
3.0%
△
F11.08
Overvoltage Stall
Mode 2 Integral Time
0.000
~
1.000s
0.010s
△
F11.10
Protection action 1
Unit's place:
Bus undervoltage
00330
×
0: Fault reported and coast to stop
1: Stop according to the stop mode
2: Fault reported but continue to
run
3: Fault protection disabled
Ten's digit :Power input phase
Loss (Err09)(Same as unit's
place )
Hundred's digit :Power output
phase loss(Err10)(Same as unit's
place )
Thousand's digit:Motor overload
(Err11)(Same as unit's place )
Ten thousand's digit:Inverter
overload(Err11)(Same as unit's
place )
F11.11
Protection action 2
External equipment fault
(
Err13)
00000
×
0: Fault reported and coast to stop
1: Stop according to the stop mode
2: Fault reported but continue to
run
Ten's digit: EEPROM read/write
fault (Err15) (Same as unit's place)
Hundred's digit: Communication
overtime error (Err18) (Same as
unit's place)
Thousand's digit: PID feedback
loss (Err19) (Same as unit's place)
Ten thousand's digit: Continuous
running time reached (Err20)
(Same as unit's place)
F11.12
Protection action 3
Unit's place: Module temperature
detection disconnection
(
Err24)
00030
×