OBID
i-scan
®
UHF
Manual
ID ISC.LRU3000/3500
FEIG ELECTRONIC GmbH
Page 86 of 193
H90202-7e-ID-B.docx
KEEPALIVE:
(HostInterface.LAN.Keepalive.Enable)
0x00: keepalive option disabled
0x01: keepalive option enabled
KEEP-CNT: (HostInterface.LAN.Keepalive.RetransmissionCount)
Specify the maximum number of retransmissions. This is the number of times that the
reader re-transmits a keepalive packet to the host to check for connectivity. The valid range
is 1..255.
KEEP-IDLE:
(HostInterface.LAN.Keepalive.IdleTime)
The time the connection needs to remain idle before the reader starts sending keepalive
probes. The valid range is 1..65535 sec.
KEEP-INTERVAL:
(HostInterface.LAN.Keepalive.IntervalTime)
Set the Keepalive Interval. This is the polling frequency used to determine if a keepalive ex-
change is needed. This interval is used when the connection failed. The valid range is
1..65535 sec.
NOTE:
The command
8.5. [0x8C] Reset Configuration
Changing of this parameter only becomes effective after writing /saving this configuration
block to EEPROM and a