7.11. CFG12: Read Mode - Filter
Byte
0
1
2
3
4
5
6
Contents
VALID-TIME
1
TR-ID
IN-EV-FLT
Default
0x0037
5,5sec.
0x01
0x00
0x00
0x01
0x00
Byte
7
8
9
10
11
12
13
Contents
ST-EV-FLT
0x00
0x00
0x00
0x00
0x00
0x00
Default
0x00
VALID-TIME:
(only for Buffered Read Mode, Notification Mode and Scan Mode)
(OperatingMode.BufferedReadMode.Filter.TransponderValidTime)
(OperatingMode.NotificationMode.Filter.TransponderValidTime)
(OperatingMode.ScanMode.Filter.TransponderValidTime)
(0...65535 x 100 ms = 0 ms ... 6553,5 sec)
The period of time during which a Transponder will not be reported a 2
nd
time.
TR-ID:
(only for Buffered Read Mode and Notification Mode)
TR-ID sets the parameters for Transponder identification.
If several Transponders have the same content in the addressed data block, only one da-
taset will be generated.
Byte
2
3
4
5
Function
TR-ID-
SOURCE
TR-ID-DB-ADR
TR-ID-DB-N
TR-ID-SOURCE: (OperatingMode.Miscellaneous.TransponderIdentification.Source)
Sets the data source for Transponder identification.
b0
data block
1
Serial Number
TR-ID-DB-ADR: (Operating-
Mode.Miscellaneous.TransponderIdentification.DataBlockNo)
Sets the address of the data block for Transponder identification. If ID-SOURCE
selects the Serial Number as data source, the ID-DB-ADR will be ignored.