OBID
i-scan
®
UHF
Manual
ID ISC.LRU3000/3500
FEIG ELECTRONIC GmbH
Page 56 of 193
H90202-7e-ID-B.docx
Byte Order DB: (OperatingMode.BufferedReadMode.DataSource.ByteOrderOfData)
(OperatingMode.NotificationMode.DataSource.ByteOrderOfData)
(OperatingMode.ScanMode.DataSource.ByteOrderOfData)
b0:
MSB first
b1:
LSB first
ANT:
(OperatingMode.BufferedReadMode.DataSelector.AntennaNo)
(OperatingMode.NotificationMode.DataSelector.AntennaNo)
(OperatingMode.ScanMode.DataSelector.AntennaNo)
b0:
the number of the antenna will not be stored
b1:
the number of the antenna (1-4) where the Transponder has been
detected, will be stored.
NOTE:
If Number of Antenna is enabled the checkbox for Antenna Extended must be disabled
TIMER:
(OperatingMode.BufferedReadMode.DataSelector.Time)
(OperatingMode.NotificationMode.DataSelector.Time)
(OperatingMode.ScanMode.DataSelector.Time)
b0:
no internal system timer
b1:
internal system timer will be active
DATE:
(OperatingMode.BufferedReadMode.DataSelector.Date)
(OperatingMode.NotificationMode.DataSelector.Date)
(OperatingMode.ScanMode.DataSelector.Date)
b0:
no date is transferred BRM Data record
b1:
date is transferred BRM Data record
NOTE:
The internal system timer is not a real time clock (RTC) and the accuracy cannot be guaran-
teed.