OBID
i-scan
®
UHF
Manual
ID ISC.LRU3000/3500
FEIG ELECTRONIC GmbH
Page 62 of 193
H90202-7e-ID-B.docx
TR-ID-DB-N: (Operating-
Mode.Miscellaneous.TransponderIdentification.NoOfDataBlocks)
Sets the number of data blocks to be read for Transponder identification. If ID-
SOURCE selects the Serial Number as data source, the ID-DBN will be ignored.
NOTE:
Changing of TR-ID only becomes effective after writing / saving configuration block CFG12
to EEPROM and reset of the AC-Controller with
The address TR-ID-DB-ADR must be in the range of the selected data blocks:
DB-ADR
≤
TR-ID-DB-ADR
≤
DB-ADR
1
+ DB-N
1
– 1.
IN-EV-FLT:
(OperatingMode.BufferedReadMode.Filter.Enable_InputXEvent) X=1-5
(OperatingMode.NotificationMode.Filter.Enable_InputXEvent) X=1-5
Input Event Filter
Bit
7
6
5
4
3
2
1
0
Function
-
-
-
Input5
Input4
Input3
Input2
Input1
Input1...5:
b0
input event will not be notified
b1
input event will be notified
ST-EV-FLT:
Status Event Filter
Bit
7
6
5
4
3
2
1
0
Function
-
-
-
-
-
-
TIMEOUT
BRM
TIMEOUT:
(OperatingMode.BufferedReadMode.Filter.Enable_TimeoutEvent)
(OperatingMode.NotificationMode.Filter.Enable_TimeoutEvent)
b0
timeout event while active BRM or Notification mode will not be notified
b1
timeout event while active BRM or Notification mode will be notified
9
DB-ADR, DB-N of CFG11