OBID
i-scan
®
UHF
Manual
ID ISC.LRU3000/3500
FEIG ELECTRONIC GmbH
Page 116 of 193
H90202-7e-ID-B.docx
8.4. [0x8B] Write Configuration
The Write Configuration Protocol is defined to change the complete or parts of reader configura-
tion.
This protocol is an extension of [0x81] Write Configuration and realizes many improvements:
1. several destinations are addressable
2. one or all configuration blocks can be written
3. the address range is up to 65535 configuration blocks for each destination
4. different configuration locations for each destination are addressable
5. protocol ignores write protected configuration blocks and writes only writable configuration
blocks
Host
→
Reader:
Byte
1
2 + 3
4
5
6
7
Contents
0x02
LENGTH
COM-ADR
[0x8B]
DEVICE
BANK
8
9
10
11, 12
13...
2 byte
MODE
CFG-N
BLOCK-SIZE
CFG-ADR
CFG-DATA
CRC16
Repeated CFG-N times
Host
←
Reader (STATUS = 0x00)
Byte
1
2+3
4
5
6
7 + 8
Contents
0x02
LENGTH
COM-ADR
[0x8B]
0x00
CRC16
DEVICE:
The DEVICE identifies the target controller inside the reader. The following devices are
acceptable:
DEVICE
Value
RF-Controller
0x02