7.10.
CFG11: Read Mode – Read Data
The parameters of the configuration block CFG11 contain Buffered Read Mode and Scan Mode
settings. To enable Buffered Read Mode the BRM bit in the READER-MODE register of the confi-
guration block
must be set. It is useful to enable “Anticollision Se-
if there is a large or unknown number of Transponders in the
antenna field. The Buffered Read-Mode can be used with the Antenna Multiplex Mode. The para-
meters for this function have to be configured in
7.14. CFG15: Antenna Multiplexing
Byte
0
1
2
3
4
5
6
Contents TR-DATA-1
TR-DATA-2
TR-DATA-3
BANK
DB-ADR
Default
0x71
0x00
0x02
0x01
0x0000
Byte
7
8
9
10
11
12
13
Contents
DB-N
D-START
D-LGT
Default
0x00
0x0001
0x0004
TR-DATA-1
1 2
:
Selects the data types for read operation.
Bit
7
6
5
4
3
2
1
0
Function
Exten-
sion
DATE
TIMER
ANT
Byte
Order
DB
DB
SNR
SNR: (OperatingMode.BufferedReadMode.DataSelector.UID)
(OperatingMode.NotificationMode.DataSelector.UID)
(OperatingMode.ScanMode.DataSelector.UID)
b0:
no Serial Number will be stored
b1:
Serial Number will be stored
DB:
(OperatingMode.BufferedReadMode.DataSelector.Data)
(OperatingMode.NotificationMode.DataSelector.Data)
(OperatingMode.ScanMode.DataSelector.Data)
b0:
no data block will be stored
b1:
data block will be stored
7
A reasonableness check is performed by writing this parameter to the Reader. If an error occurs the Read-
er answers with STATUS = [0x11].