OBID
i-scan
®
UHF
Manual
ID ISC.LRU3000/3500
FEIG ELECTRONIC GmbH
Page 36 of 193
H90202-7e-ID-B.docx
FLASH-IDLE:
(DigitalIO.Output.NoX.IdleFlashMode) x=1,2
(DigitalIO.Relay.NoX.IdleFlashMode) x=1-3
Allocates a flashing-frequency to each output.
Bit
15
14
13
12
11
10
9
8
Function
REL1 frq
OUT2 frq
OUT1 frq
0
0
7
6
5
4
3
2
1
0
REL2 frq
REL3 frq
0
0
0
0
Bit combination
flashing frequency
b11
b10
b01
b00
1 Hz
2 Hz
4 Hz
8 Hz
IN-ACTIVE: (DigitalIO.Input.NoX.Mode) x=1-5
Determines if the input is active with a closed or open contact:
b0:
closed contact activates input
b1:
open contact activates input
OUT1-TIME and RELx-TIME (x=1,2):
(DigitalIO.Output.No1.SettlingTime)
(DigitalIO.Relay.NoX.SettlingTime) x=1,2
Defines the holding time of the digital output OUT1 / RELx. If the Reader receives a valid
Transponder response the antenna assigned to the output by
(Assignment – output to antenna read event)
is activated for the value in OUT1 / RELx -
TIME.
If OUT1 / RELx -TIME is zero the function is disabled.
If OUT1 / RELx is high in idle mode, OUT1 / RELx will low for OUT1 / RELx -TIME.
If the flash mode is enabled, the output goes low.
Range: 0x0000 ... 0xFFFF ( * 100ms) = 0s ... 6553,5s.
Bit
7
6
5
4
3
2
1
0
Function
0
0
0
IN5
IN4
IN3
IN2
IN1