OBID
i-scan
®
UHF
Manual
ID ISC.LRU3000/3500
FEIG ELECTRONIC GmbH
Page 193 of 193
H90202-7e-ID-B.docx
ANNEX D3: [0x83] Set Default Configuration
Using the command Set Default Configuration each configuration block can be reset to the manu-
facturer's setting.
Host
→
Reader
Byte
1
2
3
4
5...6
Contents
6
COM-ADR
[0x83]
CFG-ADR
CRC16
Host
←
Reader
Byte
1
2
3
4
5...6
Contents
6
COM-ADR
[0x83]
STATUS
CRC16
CFG-ADR:
Bit
7
6
5
4
3
2
1
0
Function
LOC
MODE
CFGn: Address of Configuration Block
CFGn:
memory-address of the required configuration block
MODE:
specifies one or all configuration blocks
b0
configuration block specified by CFGn
b1
all configuration blocks
LOC:
specifies the location of the configuration block
b0
RAM
b1
RAM and EEPROM
NOTE:
A set default configuration command with reserved configuration blocks will cause an error
code.
48