7.5. CFG4: Transponder Parameters
The parameters of the CFG4 configuration block contain general Transponder settings.
Byte
0
1
2
3
4
5
6
Contents
0x00
0x00
0x00
0x00
0x05
0x00
0x80
Default
Byte
7
8
9
10
11
12
13
Contents
0x00
0x00
0x00
0x00
WR-OPTION
IDDIB
TID-Length
Default
0x01
0x00
0x00
WR-OPTION: (Transponder.Miscellaneous.WriteOption)
Defines the number of Blocks to be written by one write command. By default information
issued by the Write Multiple Blocks command are written blockwise.
Bit
7
6
5
4
3
2
1
0
Function
Number of Blocks
0x01 – 1 Block (default)
0x02 – 2 Blocks
….
NOTE:
The number of Blocks to be written at once is depending on the used transponder chip.
Please check the number of supported blocks in the datasheet.
If a Write Multiple Blocks command with the configured settings failed the reader will auto-
matic retry the write command with Number of Blocks set to 1.
IDDIB
(Identifier Data Interpretation Byte)
:
(Transponder.Miscellaneous.IdentifierInterpretationMode)
Defines in which way the Reader interprets and displays the Identifier data read during
inventory process by using the inventory command or in Buffered Reader Mode.
0x00 – automatic Mode (IDD Type is automatic set by the Reader)
0x02 – EPC and TID
NOTE:
If IDDIB is 0x02 then only the TID must be used to address commands (e.g. read, write...) to
the tag.