OBID
i-scan
®
UHF
Manual
ID ISC.LRU3000/3500
FEIG ELECTRONIC GmbH
Page 180 of 193
H90202-7e-ID-B.docx
IN
=
Input number
Bit
7
6
5
4
3
2
1
0
Function
-
-
-
Input5
Input4
Input3
Input2
Input1
Input1...5
b0
Input inactive
b1
Input active
STATUS
:
Bit
7
6
5
4
3
2
1
0
Function
Timeout
BRM
BRM
b0
BRM -> OFF
b1
BRM -> ON
Timeout
b0
BRM interrupt due to Input state
b1
Timeout due to Trigger-Hold-Time timeout
ANT-CNT
= antenna counter
Shows the antennas on which a transponder was read.
ANTx
= antenna number
The antenna number depends on the number of the output of the multiplexer and
the connection of that multiplexer in the structure. The decimal places of the an-
tenna number describe the active outputs of the multiplexers on all 3 levels to
switch to the antenna.
ANT-CNT = (Level 2 Mux Channel) * 10 + (Level 1 Mux Channel) * 1
Example:
– Mux on output 2 Level 1
– Mux on output 4 Level 2
ANT-CNT = 4 * 10 + 2 * 1 = 42
RSSIx
= Receive signal strength identification