9.9. [0x74] Get Input
With this protocol the actual status of the digital inputs IN1...IN4 can be determined at any time.
Host
→
Reader
Byte
1
2
3
4...5
Contents
5
COM-ADR
[0x74]
CRC16
Host
←
Reader
Byte
1
2
3
4
5
6...7
Contents
7
COM-ADR
[0x74]
STATUS
INPUTS
CRC16
INPUTS:
Bit
7
6
5
4
3
2
1
0
Function
-
-
-
IN5
IN4
IN3
IN2
IN1
b0
digital input = inactive
b1
digital input = active
NOTE:
If the trigger is enabled in Buffered Read Mode the input IN1 isn't available for common use.