OBID
i-scan
®
UHF
Manual
ID ISC.LRU3000/3500
FEIG ELECTRONIC GmbH
Page 145 of 193
H90202-7e-ID-B.docx
OUT-TIME:
By the values defined by “OUT-TIME”, the outputs can be activated temporary limited or
unlimited.
An exception is the time value 0 and 65535 (0xFFFF) (see following table).
0x0001
1 x 100ms
-> 100ms
...
...
0xFFFE
65534 x 100ms -> 1:49:13 h
0xFFFF
continuously active
NOTE:
In order to reset a continuously active time, OUT-TIME = 1 has to be sent to the Reader,
which effects a change to the idle status after 100 ms.
The continuous activation is being set back after a reset or a power failure.
9.8.1. Set Output Examples
Example No. 1:
OUT1 is alternating with 4 Hz for 500 ms.
REL1 is not activated for 200 ms.
REL2 is activated for 1000ms
REL3 and REL4 are unchanged
OUT-N
OUT-NR
OUT-S
OUT-TIME
0x0003
0x01
0x07
0x0005
OUT-NR
OUT-S
OUT-TIME
0x81
0x02
0x0002
OUT-NR
OUT-S
OUT-TIME
0x82
0x01
0x000A