OBID
i-scan
®
UHF
Manual
ID ISC.LRU3000/3500
FEIG ELECTRONIC GmbH
Page 133 of 193
H90202-7e-ID-B.docx
Mode = 0xFF (All Info Records)
Return of all Info records in one Response.
Host
←
Reader
Byte
1
2
3
4
5
Contents
n
COM-ADR
[0x66]
STATUS
DATASETS
7
8..37
n-1, n
MODE
DATA
CRC16
Repeated DATASETS times
MODE
Mode byte
DATA (Mode 0xFF):
Data record according to the definition in the previous sections.
The data record is always 30 byte long and information begins always
with byte 0. Unused bytes must be filled with 0x00.
25