DATA:
Requested number of data sets from the data buffer. Only selected data will be trans-
ferred to the host. See chapter
Each data set has the following structure:
Data Type
DATA
Record Length
byte no.
1
2
MSB RecLen
LSB RecLen
Serial Number
byte no.
1
2
3
3+LEN
TR-TYP
IDDT
IDD-LEN
IDD
data blocks
byte no.
1
2
3
4…4+DB-N*DB-SIZE
DB-N
DB-SIZE
DB
Timer
byte no.
1...4
TIMER
date
byte no.
1...5
DATE
Antenna
byte no.
1
ANT-NO
Input
byte no.
1
1
IN
STATUS
Antenna-Extended
byte no.
1
2
3
4...7
ANT-CNT
ANTx
RSSIx
reserved
Repeated ANT-CNT times
ANT-NO
= Antenna number
ANT is a bit field. If the tag is read on more than one antenna and the configura-
tion option "all antenna ports act as one reading point" is set, the corresponding
bits of each antenna were the Transponder is read will be set in the bit field.
Bit
7
6
5
4
3
2
1
0
Function
-
-
-
-
ANT4
ANT3
ANT2
ANT1
ANT1...4
b0
this antenna has not read transponder data
b1