Condition:
(OperatingMode.BufferedReadMode.Trigger.Condition)
(OperatingMode.NotificationMode.Trigger.Condition)
(OperatingMode.ScanMode.Trigger.Condition)
b0:
Level Triggered:
RF Field will be switched on with the rising edge. Trigger Hold Time
starts to run with the falling edge
b1:
Edge Triggered
RF Field will be switched on with the rising edge. Trigger Hold Time
starts to run with the rising edge.
Unlimited Valid Time:
(OperatingMode.BufferedReadMode.Trigger.Enable_UnlimitTransponderValidTime)
(OperatingMode.NotificationMode.Trigger.Enable_UnlimitTransponderValidTime)
(OperatingMode.ScanMode.Trigger.Enable_UnlimitTransponderValidTime)
b0:
Valid Time is limited to one Trigger Period:
The Valid Time (s. CFG12) is restarted with each Trigger Period and
thus not longer than one Trigger Period.
b1:
Unlimited Valid Time:
The Valid Time (s. CFG12) is applicable for more than one Trigger Pe-
riod.
TRIGGER-USE-A:
TRIGGER-USE-B:
Defines whether Input 1, Input 2, Input 3, Input 4 (Trigger-Use-A) or Input 5 (Trigger-Use-B)
is used as a trigger. If the Input is used as a trigger you can chose if the Trigger start or
stops the operation.
TRIGGER-USE-A
Bit
7
6
5
4
3
2
1
0
Function
TU 4
TU 3
TU 2
TU 1
TRIGGER-USE-B
Bit
7
6
5
4
3
2
1
0
Function
-
-
-
TU 5