ID ISC.LRU3000/3500
FEIG ELECTRONIC GmbH
Page 27 of 193
H90202-7e-ID-B.docx
NOTE:
Changing of BAUD only becomes effective after writing / saving configuration block CFG1
to EEPROM and a reset of the Reader.
The Reader sets the baud rate to 38400 baud, if the user sets an invalid baudrate.
TRANS-FORM
:
By means of this byte, several parameters for the data transmission format of the asyn-
chronous interface can be defined.
Bit
7
6
5
4
3
2
1
0
Function
0
0
0
0
S
D
P
P: (HostInterface.Serial.Parity)
Kind of Parity
b00:
no Parity
b01:
even Parity
b10:
odd Parity
b11:
- do not use –
D: (HostInterface.Serial.Databits)
Number of Data Bits
b0:
8 Data Bits
b1:
- do not use –
S: (HostInterface.Serial.Stopbits)
Number of Stop Bits
b0:
1 Stop Bit
b1:
- do not use –
NOTE:
Changing of TRANS-FORM only becomes effective after writing / saving configuration block
CFG1 to EEPROM and reset of the Reader.
Always 8 Data Bits and 1 Stop Bits should be used.
4
A reasonableness check is performed by writing this parameter to the Reader. If an error occurs the Read-
er answers with STATUS = 0x11.