7.14.
CFG15: Antenna Multiplexing I
The parameters in CFG15 are used to configure for multiplexing of antennas in Buffered Read
Mode, Notification Mode and Scan Mode.
Byte
0
1
2…9
10
11
12
13
Contents
MUX-MODE
ANT_OUT
-
ANT_OUT_
EXT_1
ANT_OUT_
EXT_2
ANT_OUT_
EXT_3
ANT_OUT_
EXT_4
Default
0x01
0xFC
0x00 0x00
0x00 0x00
0x00
MUX-MODE:
Activates or deactivates multiplexing and determines when the next output is selected.
Bit
7
6
5
4
3
2
1
0
Function
0
0
0
0
0
0
0
Multiplexing
Multiplexing: (AirInterface.Multiplexer.Enable)
b0:
disable
b1:
enable
ANT_OUT:
Specifies the antenna outputs used in BRM Mode, Notification Mode and Scan Mode
Bit
7
6
5
4
3
2
1
0
Function
ANT_
SEL
ANT_OUT_INT
ANT_OUT_INT_NR
ANT4
ANT3
ANT2
ANT1
ANT_SEL: (AirInterface.Multiplexer.UHF.Internal.Antenna SelectionMode)
b0:
ANT_OUT_INT_NR defines the number of antennas of the internal multiplexer.
The reader starts always with antenna 1.
b1:
ANT_OUT_INT is a bit field and defines the antennas which are
used for the internal multiplexing.
ANT_OUT_INT: (AirInterface.Multiplexer.UHF.Internal.SelectedAntennas)
This parameter is depended of Bit ANT_SEL
b0:
Antenna disabled
b1: