OBID
i-scan
®
UHF
Manual
ID ISC.LRU3000/3500
FEIG ELECTRONIC GmbH
Page 140 of 193
H90202-7e-ID-B.docx
MODE = 0x05:
Detail information of Flags A if ID ISC.ANT.UMUX is used
Byte
3
4
5
6
7
Contents
Control
UMUX1
reserved
reserved
Control
UMUX2
reserved
8
9
10
11
12
reserved
Control
UMUX3
reserved
reserved
Control
UMUX4
13
14
reserved
reserved
Control:
Indicates the status of the connected multiplexer antennas
Bit
8
7
6
5
4
3
2
1
Function
Chn8
Chn7
Chn6
Chn5
Chn4
Chn3
Chn2
Chn1
b0
IZI = 50 Ohm
b1
IZI < > 50 Ohm
MODE = 0x20:
ASCII-String with a description of the error.