OBID
i-scan
®
UHF
Manual
ID ISC.LRU3000/3500
FEIG ELECTRONIC GmbH
Page 163 of 193
H90202-7e-ID-B.docx
10.2.1. [0x18] Kill
This command writes one or more data blocks by using the kill command for C1G2. The trans-
ponder will never respond to any command afterwards.
REQUEST-DATA
Byte
4
5
1 Byte
EPC_LNG
Bytes
Contents
0x18
MODE
EPC_LNG
EPC
1 Byte
K_PW_LNG
Bytes
(1 Byte)
K_PW_LNG
K_PW
(RECOM Bits)
RESPONSE-DATA (STATUS = 0x95)
Byte
5
Contens
EPC Class1
Gen2 ERROR
MODE:
Bit
7
6
5
4
3
2
1
0
Function
0
0
0
EPC_LF
RECOM
ADR
ADR:
b000
non-addressed
b001
addressed
EPC_LF:
If this bit is set the parameter EPC_LNG must inserted into the protocol.
b1:
The protocol includes the parameter EPC_LNG. The EPC has a variable
length as defined in EPC_LNG.
RECOM:
b1:
If this bit is set the Recommissioning Bits will be inserted into the proto-
col.
EPC_LNG:
Is a optional parameter and depends on the setting of EPC_LF (see MODE). EPC_LNG
defines the length of the following EPC field.