OBID
i-scan
®
UHF
Manual
ID ISC.LRU3000/3500
FEIG ELECTRONIC GmbH
Page 154 of 193
H90202-7e-ID-B.docx
ANT:
b0
no antenna information will be send
b1
antenna information (ANT_CNT, ANT_NR, ANT_STATUS, RSSI) will be
send
TR-TYPE:
ANNEX A: Codes of Transponder Types
IDDT:
(Identifier Data Type)
Defines the type of Data transmit beginning at Byte 10. Possible Inventory Data Type See:
ANNEX B: Codes of Identifier Data Bytes (IDDT)
IDD-LEN:
Identifier Data Length defines the length of the IDD in Byte.
IDD:
Identifier Data of the Transponder
ANT_CNT:
Number of antennas where transponder was read
ANT_NR:
Number of the antenna (1...255)
ANT_STATUS:
The ANT_STATUS can be 0x00 (OK) or
0x83 (RF communication error) See:
ANNEX C: Index of Status Bytes
RSSI:
Received Signal Strength Identification in dBm
NOTE:
This command supports all Transponders.
If the STATUS byte of the protocol frame has the value 0x94 more IDD can be read out of the
Reader with MORE = b1.