OBID
i-scan
®
UHF
Manual
ID ISC.LRU3000/3500
FEIG ELECTRONIC GmbH
Page 159 of 193
H90202-7e-ID-B.docx
10.1.3. [0x24] Write Multiple Blocks
This command writes one or more data blocks.
REQUEST-DATA
Byte
4
5
1 Byte
UID_LNG
Bytes
1Byte
Contents
0x24
MODE
UID_LNG
UID
BANK
1 Byte
A_PW_LGT
Bytes
1 or 2 Bytes
( def. by
EXT_ADR)
1 Byte
1 Byte
DB-N times
DB-SIZE
Bytes
A_PW_LGT
A_PW
DB-ADR
DB-N
DB-SIZE
DB
Repeated DB-
N times
RESPONSE-DATA (STATUS = 0x03)
Byte
5
(6)
Contents
DB-ADR-E
(DB-ADR-E)
RESPONSE-DATA (STATUS = 0x95)
Byte
5
6
(7)
Contents
EPC Class1
Gen2 ERROR
DB-ADR-E
(DB-ADR-E)
MODE:
Bit
7
6
5
4
3
2
1
0
Function
0
0
EXT_ADR
UID_LF
ADR
ADR:
b000
non-addressed
b001
addressed
UID_LF:
If this bit is set the parameter UID_LNG must inserted into the protocol.
b0:
The protocol UID_LNG doesn't include the UID_LNG byte and
the UID field has a fixed length of 8 byte, from byte 6 to byte 13.
b1:
The protocol includes the parameter UID_LNG. The UID has a variable
length as defined in UID_LNG.