ENABLE_TERMINATION_RESISTOR:
(HostInterface.Serial.RS4xx.Enable_TerminationResistors)
Bit
7
6
5
4
3
2
1
0
Function
0
0
0
0
0
0
0
TERM
TERM:
This bit activates the RS485 bus termination on the reader RS485 interface
b0:
disabled (default)
b1:
enabled
TR-RESPONSE-TIME: (AirInterface.TimeLimit)
By means of this parameter the maximum duration for the Transponder command can be
defined.
The TR-RESPONSE-TIME starts after the Reader has received a new command. At the
latest after the TR-RESPONSE-TIME elapsed the Reader will send an answer protocol. In
this case, the current commands between Reader and Transponder are aborted. If this
time is too short the Interface Status “0x83 RF Communication Error“ will appear.
max. response duration
TR-RESPONSE-TIME
0...65535 * 5 ms
NOTE:
TR-RESPONSE-TIME has no effect with the protocols for Reader Configuration and the pro-
tocols for Reader Control.
The TR-RESPONSE Time must be < “Block Timeout” in the Host Interface settings.
SCAN-INTERFACE: (OperatingMode.ScanMode.Interface)
Selection of the communication port for Scan-Mode
IF-NO:
Interface Number
b000:
RS232
b001:
RS485
b010:
- do not use –
b011:
Data clock
b1xx:
- do not use –
Bit
7
6
5
4
3
2
1
0
Function
-
-
DC-Format
IF-NO