8. Protocols for Reader Configuration
Via the protocols for Reader configuration, the Reader can be adapted to individual conditions of
application within wide limits.
8.1. [0x87] Set System Time and Date
The Set System Time and Date command sets the internal system timer of the ACC.
Host
→
Reader
Byte
1
2
3
4...8
8..12
12...13
Contents
13
COM-ADR
[0x87]
DATE
TIMER
CRC16
Host
←
Reader
Byte
1
2
3
4
5...6
Contents
6
COM-ADR
[0x87]
STATUS
CRC16
DATE:
Byte
4
5
TIME
century
year
0...99
0...99
6
7
8
month
day
time zone
1...12
1...31
0...23
TIMER:
Byte
9
10
11...12
TIME
h
min
ms
0...23
0...59
0...59999
NOTE:
After setting the system time and date a
11.7. [0x33] Initialize Buffer
fered Read Mode or Notification Mode is used.